5E-AA2288 Automatic Cadmium Analyzer
The 5E-AA2288 Automatic Cadmium Analyzer directly analyzes cadmium in solid and liquid samples, eliminating the need for sample preparation, chemical reagents, or an external high-pressure gas source. It offers greater efficiency, accuracy, stability, and reliability compared to Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS).
Product Category: Analytical Instruments, Agriculture & Environment, Coal, Metal Ore Mining, Cement & Non-metallic resources, Cadmium Analyzer.
Features
High Automation and Efficiency
- Auto-loader holds up to 45 samples, with the ability to add samples on demand, ensuring quick, uninterrupted analysis.
- Integrated carousel loader for mass sample addition and pre-weighing to streamline processing
Wide Range of Application
- The unique thermal decomposition unit handles various sample matrices.
- Standard curve creation with a standard solution for environmental protection.
- Capable of testing cadmium content from 0.002 mg/kg to 100 mg/kg in solid and liquid samples, including rice, baby food, and soils.
Cost Saving
- Built-in gas device eliminates the need for an external high-pressure gas source.
- Reusable high-purity quartz boats reduce material costs.
Application
The 5E-AA2288 Automatic Cadmium Analyzer is widely used in various industries, including food safety, environmental monitoring, agriculture, coal and other mining and scientific research. Its advanced technology and robust design make it the ideal choice for accurate and efficient cadmium analysis.
Reliable, Automated, and Cost-Effective
The 5E-AA2288 Automatic Cadmium Analyzer is one of the most reliable analyzers used to determine total content of cadmium in various samples.
For more information or inquiries, please contact us.
📩 Contact us for more information or to request a demonstration.
Datasheet
| Specification | Details |
| Model | 5E-AA2288 |
| Conforms to Method | T/CAIA/SH014, T/CAIA/SH015, DB43/T 2354, DB43/T 1812, NY/T 4433 |
| Method | Electrothermal vaporization atomic absorption |
| Sample Matrix | Solid and liquid |
| Sample Mass | 0.1g |
| Light Source | HCL-Cd |
| Wavelength | 228.8nm |
| Baseline Stability | Static baseline ±0.001Abs/30min |
| Analysis Range | 0.002mg/kg-100mg/kg |
| Analysis Time | 3 minutes |
| Repeatability | RSD < 3% @ 20ng Cd |
| Energy Consumption | Peak < 3000W |
| Power Supply | AC220 ±10%, 50/60 Hz |
| Net Weight | 40kg |
| Dimensions (L×W×H) | 590mm × 460mm × 330mm |